亚洲444eee在线观看-美国少妇在线观看免费-九月婷婷-亚洲色图综合网-诱惑の诱惑筱田优在线播放-亚洲第十页-国产欧美精品一区二区三区-伊人亚洲综合-欧美乱轮视频-麻豆出品-亚洲精品一区二区三区影院忠贞-√天堂资源地址在线官网-欧美a级在线观看-91香蕉视频在线看-好看的国产精品-国产白嫩美女无套久久-国产成人精品无码片区在线-不卡av电影在线-白丝jk喷水-成人ay-中字韩国乱理伦电影-欧美精品成人一区二区三区四区-美女网站一区-欧美二三四区-欧美日韩xxxxx-嫩草视频一区二区三区-色偷偷av老熟女-337p日本欧洲亚洲大胆精品

歡迎來北京祥生興業科技有限公司!我們將為您提供周到的服務!
相關文章Related articles
首頁 > 產品中心 > > > 氨基酸,酰基肉堿干血斑質控

產品名稱:氨基酸,酰基肉堿干血斑質控

產品型號:0191,0192,0193

產品報價:

產品特點:

0191,0192,0193 MassCheck氨基酸,酰基肉堿干血斑質控, 用于監控定量測定氨基酸,酰基肉堿和琥珀酰丙酮在干血分析方法的準確度和精確度Chromsystems

免費咨詢:13681184382

發郵件給我們:702140183@qq.com

分享到:

0191,0192,0193氨基酸,酰基肉堿干血斑質控的詳細資料:

溫馨提示:僅用于科研,不可用于臨床治療

新生兒遺傳代謝疾病檢測,串聯質譜分析方法試劑盒LC-MS/MS 非衍生化
 

  • All required and isotope labelled standards included

  • Dried blood spot controls included

  • Direct sample injection without derivatisation

  • High selectivity and sensitivity by MS/MS detection

This Chromsystems reagent kit allows the very fast and reliable determination of amino acids and acylcarnitines from dried blood spot samples as part of the newborn screening for amino acid and fatty acid metabolic disorders using tandem mass spectrometry. Sample preparation is based on effective extraction of the analytes from the filter card without any further sample preparation steps required. The test utilises stable isotope labelled internal standards for calibration and measurement to ensure reliable and precise quantification of the analytes. Due to the time saving sample preparation and high precision of the MRM method, this direct injection kit stands out from the derivatised method. On the other hand lower sensitivity and interferences from isobaric substances (e.g. C5DC and C6OH) in acylcarnitines analyses may occur.

Specifications

 

Linearity:Amino acids: 2000-2400 µmol/l
(Acyl-)carnitines: 25-200 µmol/l
Limit of quantification:Amino acids: 2.5-30 µmol/l
(Acyl-)carnitines: 0.1-1.6 µmol/l
Recovery:Amino acids: 64-94 %
(Acyl-)carnitines: 63-102 %
Intra-assay:Amino acids: 2-11 %
(Acyl-)carnitines: 3-12 %
Inter-assay:Amino acids: 3.5-18 %
(Acyl-)carnitines: 4.8-14 %
Analysis time:< 2 min

 

Cutoff thresholds

 

Amino acids:ca. 30 to 1000 µmol/l
free carnitine:ca. 55 µmol/l
Acylcarnitines:ca. 0.2 to 10 µmol/l

 

LC-MS/MS parameters

LC-MS/MS system. No HPLC column is required.

 

Injection volume:10 µl
Flow gradient:20 to 600 µl/min
Autosampler rinsing solution:Rinsing Solution (57007)
MS/MS Mode:MRM
Mass transitions: 
Alanine90 > 44
Alanine-D494 > 48
Arginine175 > 70
Arginine-D7182 > 77
Aspartic acid134 > 116
Aspartic acid-D3137 > 119
Citrulline176 > 113
Citrulline-D2178 > 115
Glutamic acid148 > 130
Glutamic acid-D5153 > 135
Glycine76 > 30
Glycine-13C2-15N79 > 32
Leucine132 > 86
Leucine-D3135 > 89
Methionine150 > 133
Methionine-D3153 > 136
Ornithine133 > 70
Ornithine-D6139 > 76
Phenylalanine166 > 120
Phenylanlanine-D5171 > 125
Proline116 > 70
Proline-D7123 > 77
Tyrosine182 > 136
Tyrosine-D4186 > 140
Valine118 > 72
Valine-D8126 > 80
Free carnitine162 >85
Carnitine-D9171 > 85
C2-Carnitine204 > 85
C2-Carnitine-D3207 > 85
C3-Carnitine218 > 85
C3-Carnitine-D3221 > 85
C4-Carnitine232 > 85
C4-Carnitine-D3235 > 85
C5-Carnitine246 > 85
C5-Carnitine-D9255 > 85
C5DC-Carnitine276 > 85
C5DC-Carnitine-D6282 > 85
C6-Carnitine260 > 85
C6-Carnitine-D3263 > 85
C8-Carnitine288 > 85
C8-Carnitine-D3291 > 85
C10-Carnitine316 > 85
C10-Carnitine-D3319 > 85
C12-Carnitine344 > 85
C12-Carnitine-D3347 > 85
C14-Carnitine372 > 85
C14-Carnitine-D3375 > 85
C16-Carnitine400 > 85
C16-Carnitine-D3403 > 85
C18-Carnitine428 > 85
C18-Carnitine-D3431 > 85

 

Sample preparation

  • Punch 3 mm dried blood spot disk out of the filter card into a well plate.
  • Add 100 µl Internal Standard, agitate for 20 min.
  • Inject 10 µl of the extract into the LC-MS/MS system.

 

Order no.Product
57000MassChrom® Reagent kit for the determination of amino acids and acylcarnitines from dried blood spot (LC-MS/MS)/Non Derivatised with regular 96 well plates.
For 960 analyses.
57000/FMassChrom® Reagent kit for the determination of amino acids and acylcarnitines from dried blood spot (LC-MS/MS)/Non Derivatised with 96 well filter plates.
For 960 analyses.
 Separately available components
57001Mobile Phase, 1000 ml
57002Mobile Phase, 10 x 1000 ml
57004/TInternal Standard (lyoph.), 25 ml
57004Internal Standard (lyoph.), 4 x 25 ml
57007Rinsing Solution, 1000 ml
57008Extraction Buffer, 100 ml
5701096-Well-Plates, V-Boden, 5 pcs.
55011Protective sheets for 96 well plates, 10 pcs.
5705796 Well filter plates, 5 pcs.
55013Piercable adhesive seal for 96 well plates, 10 pcs.
 Startup accessories
55015Restrictor Capillary, 1 pc.
55016Adapter collar for centrifugation, 2 pcs.
57099Tuning Mix, incl. all analytes, 2 ml
55033PEEK prefilter, 5 µm, 5 pcs.
15010PEEK prefilter housing, 1 pc.
 Chromsystems quality control material (filter spot)
0191MassCheck® Amino Acids, Acylcarnitines Dried Blood Spot Control, Bi-Level (I+II), 2 x 3 Spots
0192MassCheck® Amino Acids, Acylcarnitines Dried Blood Spot Control, Level I, 1 x 3 spots
0193MassCheck® Amino Acids, Acylcarnitines Dried Blood Spot Control, Level II, 1 x 3 spots

 

上一篇:沒有了
 相關同類產品:

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7

版權所有  ICP備案號:京ICP備2024091604號-1 管理登陸 技術支持:化工儀器網   總流量:124217  sitemap.xml