亚洲444eee在线观看-美国少妇在线观看免费-九月婷婷-亚洲色图综合网-诱惑の诱惑筱田优在线播放-亚洲第十页-国产欧美精品一区二区三区-伊人亚洲综合-欧美乱轮视频-麻豆出品-亚洲精品一区二区三区影院忠贞-√天堂资源地址在线官网-欧美a级在线观看-91香蕉视频在线看-好看的国产精品-国产白嫩美女无套久久-国产成人精品无码片区在线-不卡av电影在线-白丝jk喷水-成人ay-中字韩国乱理伦电影-欧美精品成人一区二区三区四区-美女网站一区-欧美二三四区-欧美日韩xxxxx-嫩草视频一区二区三区-色偷偷av老熟女-337p日本欧洲亚洲大胆精品

歡迎來北京祥生興業科技有限公司!我們將為您提供周到的服務!

產品名稱:類固醇激素校準品

產品型號:72038 72039

產品報價:

產品特點:

供應商:祥生興業規格:7x3ml(lyoph

免費咨詢:13681184382

發郵件給我們:702140183@qq.com

分享到:

72038 72039類固醇激素校準品的詳細資料:

溫馨提示:僅用于科研,不可用于臨床治療

  • 供應商:

    祥生興業

  • 規格:

    7 x 3 ml (lyoph.)


    72038  6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1


    Order no.: 72038
    • 11-Deoxycortisol
    • 21-Deoxycortisol
    • Aldosterone
    • Corticosterone
    • Cortisol
    • Cortisone

    MassChrom® Steroids in Serum/Plasma - LC-MS/MS

    DESCRIPTION

    6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1, lyophilised
    For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.

    These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 1 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
    These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

    TECHNICAL DATA

    Method of Analysis

    LC-MS/MS

    Content

    7 x 3 ml (lyoph.)

    Parameter

    11-Deoxycortisol, 21-Deoxycortisol, Aldosterone, Corticosterone, Cortisol, Cortisone

    Concentrations

    Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

    Substance  Unit Calibrator 1 Calibrator 2 Calibrator 3 Calibrator 4 Calibrator 5 Calibrator 6 Blank Calibrator
    Aldosterone µg/l 0.024 0.084 0.161 0.319 0.816 4.23 n.d. (< 0.014)
    Corticosterone µg/l 0.455 0.997 2.39 4.86 14.9 48.1 n.d. (< 0.175)
    Cortisol µg/l 9.02 20.1 39.1 77.5 149 290 n.d. (< 1.52)
    Cortisone µg/l 0.942 2.56 4.93 9.66 19.5 38.8 n.d. (< 0.148)
    11-Deoxycortisol µg/l 0.088 0.484 0.938 1.87 4.66 13.7 n.d. (< 0.030)
    21-Deoxycortisol µg/l 0.070 0.163 0.257 0.513 1.56 4.69 n.d. (< 0.027)
     
    n.d. = not determined, analytes under LOQ

    Reconstitution

    Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.

    Storage conditions

    Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

     

    72039  6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2


    Order no.: 72039
    • 11-Deoxycorticosterone
    • 17-OH-progesterone
    • Androstenedione
    • Dehydroepiandrosterone (DHEA)
    • Dehydroepiandrosterone sulfate (DHEA-S)
    • Dihydrotestosterone (DHT)
    • Estradiol
    • Progesterone
    • Testosterone

    MassChrom® Steroids in Serum/Plasma - LC-MS/MS

    DESCRIPTION

    6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2, lyophilised
    For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.

    These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 2 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
    These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

    TECHNICAL DATA

    Method of Analysis

    LC-MS/MS

    Content

    7 x 3 ml (lyoph.)

    Parameter

    11-Deoxycorticosterone, 17-OH-progesterone, Androstenedione, Dehydroepiandrosterone (DHEA), Dehydroepiandrosterone sulfate (DHEA-S), Dihydrotestosterone (DHT), Estradiol, Progesterone, Testosterone

    Concentrations

    Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

    Substance  Unit Calibrator 1 Calibrator 2 Calibrator 3 Calibrator 4 Calibrator 5 Calibrator 6 Blank Calibrator
    Androstenedione µg/l 0.202 0.408 0.820 1.54 5.09 15.3 n.d. (< 0.020)
    11-Deoxycorticosterone µg/l 0.049 0.098 0.146 0.288 0.721 2.80 n.d. (< 0.023)
    DHEA µg/l 1.04 5.25 10.3 15.6 30.7 60.7 n.d. (< 0.229)
    DHEAS µg/l 117 558 1097 2066 3949 5887 n.d. (< 24.4)
    Dihydrotestosterone µg/l 0.061 0.111 0.257 0.501 0.942 1.50 n.d. (< 0.042)
    Estradiol µg/l 0.043 0.105 0.260 0.530 1.59

    5.33

    n.d. (< 0.026)
    17-Hydroxyprogesterone µg/l 0.097 0.498 1.01 2.00 3.98 15.0 n.d. (< 0.040)
    Progesterone µg/l 0.180 0.805 2.11 5.27 10.3 26.0 n.d. (< 0.030)
    Testosterone µg/l 0.055 0.250 0.982 2.94 5.82 11.6 n.d. (< 0.005)
     n.d. = not determined (< LOQ)

    Reconstitution

    Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.

    Storage conditions

    Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

     

溫馨提示:不可用于臨床治療。
 相關同類產品:

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7

版權所有  ICP備案號:京ICP備2024091604號-1 管理登陸 技術支持:化工儀器網   總流量:124217  sitemap.xml